Logo specsDetail

PHOIBOS 225 HV 2D-CMOS/-CCD

Ultra High Energy Hemispherical Energy Analyzer with 2D CMOS Detector for HAXPES up tzo 15 keVwith 225 mm mean radius

The PHOIBOS 225 HV hemispherical energy analyzer is an ultra high kinetic energy analyzer solution for photoelectron spectroscopy on the material science edge. This analyzer can be operated in all relevant analysis modes, such as ARPES, XPS, UPS, as well as AES, ISS and LEISS. Its design and the modular supplementary hardware makes this analyzer the most versatile PES analyzer in the market. Its unique design allows stabe measurements up to 15 keV kinetic energy for highest XPS sensitivity in layered materials and deep core ESCA.

With a 2D CMOS HV detector is shows outstanding performance in countrate, linearity and a true pule counting mechanism. It combines a state of the art lens system with a proven hemipshere design for highest transmission and kinetic energy stability. The analyzer can be operated in transmission (XPS/UPS), angular resolved (ARPES) and magnification mode (slab imaging).

The energy analyzer sectionis equipped with 8 customizable entrance and 3 exit slits. The analyzer comes with a special and highly stable power supply, the AVC 15000, for best performance in anb extreme kinetic energy range.

A classical CCD camera detection system is available on request.

KEY FEATURES

  • Stable High Voltage Operation up to 15 keV
  • Precise and Stable Power Supply
  • HV 2D CMOS Detector with true Pulse Counting
  • Angular and Transmission Lens Modes
  • Snapshot and Sweeping Spectra Aquisition

MADE FOR THESE METHODS

2

SPECIFICATIONS

PHOIBOS 225 HV 2D-CMOS/-CCD
Performance
Energy Resolution

< 1 meV in UPS
< 7 meV in XPS
<15 meV in HAXPES

Angular Resolution

< 0.1°

k-Resolution

N/A

Acceptance Angle

±15°, ±7°, ±4° and ±3°

Lateral Resolution

< 35 µm

Smallest Acceptance Spot

100 µm

XPS Count Rates UHV

tba

Detector Channels

1285 x 730 (with Channel Binning)

Operation
Kinetic Energy Range

0-7000 eV

Pass Energies

0-550 eV Continously Adjustable

Energy Dispersion

Hemisphere

Lens Modes

Transmission Mode, Angular Resolved Mode, Magnification (Lateral Resolved) Mode

Measurement Modes

Snapshot Mode, Sweeping Mode, Fixed Energy Mode

Detector

2D CMOS Detector

Slits/Apertures

8 entrance and 3 exit slits and iris aperture

Energy Window

9% of Pass Energy

Electronics

HSA 7000 

Working Pressure

10-11 to 10-7 mbar

Mounting
Working Distance

53.3 mm

Mounting Flange

DN150CF (8" OD)

Magnetic Shielding

Double µ-Metal Shielding

Electric Isolation

> 15 keV

SPARE PARTS

6
Product image
Product description
Article No.
 
Channelplates Set - 1 pair MCP 40

Spare channelplate set for all 40 mm CCD detectors

2060009045
Phosphor screen

Spare phosphor screen for all 40 mm CCD detectors. Exchange with channelplates is recommended.

2060008804
Cu-wiregasket PHOIBOS 225 DN700COF

PHOIBOS 225 analyzer main flange gasket. Please report SN before ordering

2060002198
Rotary feedthrough for IRIS

Replacement feedthrough for PHOIBOS Release R5 & R6 iris mechanism

2060001175
Spindle with Spur and Bevel Gear for Iris

Replacement spindle for PHOIBOS Release R5 & R6 iris mechanism

2055021656
Tubus 3 with Iris

Replacement iris mechanism for PHOIBOS Release R5 & R6

2079150291

DOWNLOADS

8
Close
Your web browser is deprecated