PHOIBOS 150 HV 2D-CMOS/-CCD
High Voltage Energy Analyzer for HAXPES up to 7 keV
The PHOIBOS 150 HV analyzer series is the intrument of choice for high energy XPS analysis (HAXPES). High voltage power supplies and a highly stable analyzer design allow photoemission up to a kinectic energy of 7 keV, covering most of the existing x-ray light sources and synchrotron facilities.
This analyzer can be operated in high voltage mode and in additon in all relevant analysis modes, such as ARPES*, (AR)XPS, UPS, as well as AES, ISS and LEISS. Its design and the modular supplementary hardware makes this analyzer the most versatile PES analyzer in the market.
With a 2D CMOS detector is shows outstanding performance in countrate, linearity and a true pule counting mechanism. It combines a state of the art lens system with a proven hemipshere design for highest transmission and resolution. The analyzer can be operated in transmission (XPS/UPS), angular resolved (ARPES and ARXPS) and magnification mode (slab imaging).
The analyzer comes with a highly stable power supply, the HSA 7000, for best performance in at high and medium kinetic energy range up to 7000 eV.
A classical CCD camera detection system is available on request.
*Please note: The energy resolution of UPS and ARPES is limited due to the high voltage power supply. For Hr-ARPES the standard HSA 3500 plus can be used also with HV analyzers.
SPECIFICATIONS
Kinetic Energy Range | 0-7000 eV |
Pass Energies | 0-550 eV Continously Adjustable |
Energy Dispersion | Hemisphere |
Lens Modes | Transmission Mode, Angular Resolved Mode, Magnification (Lateral Resolved) Mode |
Measurement Modes | Snapshot Mode, Sweeping Mode, Fixed Energy Mode |
Detector | 2D CMOS Detector |
Slits/Apertures | 8 entrance and 3 exit slits and iris aperture |
Energy Window | 13% of Pass Energy |
Working Pressure | 10-11 to 10-7 mbar |
Electronics | HSA 7000 |
Energy Resolution | < 2 meV in UPS |
Angular Resolution | < 0.1° |
k-Resolution | N/A |
Acceptance Angle | ±15°, ±7°, ±4° and ±3° |
Lateral Resolution | < 35 µm |
Smallest Acceptance Spot | 100 µm |
XPS Count Rates UHV | tba |
Detector Channels | 1285 x 730 (with Channel Binning) |
Working Distance | 40 mm |
Mounting Flange | DN100CF (6" OD) |
Magnetic Shielding | Double µ-Metal Shielding |
Electric Isolation | > 10 keV |
SPARE PARTS
Spare channelplate set for all 40 mm CCD detectors
Spare phosphor screen for all 40 mm CCD detectors. Exchange with channelplates is recommended.
PHOIBOS 150 analyzer main flange gasket for Releases R5, R6, R7
Replacement feedthrough for PHOIBOS Release R5 & R6 iris mechanism
Replacement spindle for PHOIBOS Release R5 & R6 iris mechanism
Replacement iris mechanism for PHOIBOS Release R5 & R6